Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.649
Filtrar
2.
BMC Endocr Disord ; 24(1): 49, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654262

RESUMO

BACKGROUND: Papillary thyroid carcinoma (PTC), being the most common thyroid malignancy, is a slow-growing tumor and is usually limited to the thyroid. Extra thyroid extension is uncommon; besides, invasion to the vasculature seems to be extremely rare and usually indicates aggressive nature of the disease. CASE PRESENTATION: We present a case of a 40-year-old lady who referred with a palpable neck mass a month after total thyroidectomy which its histopathologic examination revealed follicular variant of PTC; the same variant as prior thyroidectomy. Preoperative ultrasonography failed to comment on the intravascular component of the mass. Surgical procedure confirmed a mass attaching and infiltrating to the internal jugular vein, which turned out to be persistent disease. CONCLUSIONS: Awareness of this entity is important for surgeons, oncologists and radiologist as it can influence patient management.


Assuntos
Carcinoma Papilar , Veias Jugulares , Câncer Papilífero da Tireoide , Neoplasias da Glândula Tireoide , Tireoidectomia , Humanos , Veias Jugulares/patologia , Veias Jugulares/diagnóstico por imagem , Feminino , Adulto , Neoplasias da Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/cirurgia , Neoplasias da Glândula Tireoide/diagnóstico , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Câncer Papilífero da Tireoide/cirurgia , Câncer Papilífero da Tireoide/patologia , Carcinoma Papilar/patologia , Carcinoma Papilar/cirurgia , Carcinoma Papilar/diagnóstico por imagem , Carcinoma Papilar/diagnóstico , Invasividade Neoplásica , Prognóstico
5.
Sci Rep ; 14(1): 8925, 2024 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637601

RESUMO

We analyzed chemoport insertion procedures to evaluate infectious morbidity and factors causing infection. This single-center retrospective study included 1690 cases of chemoport implantation between January 2017 and December 2020. Overall, chemoports were inserted in 1582 patients. The average duration of chemoport use was 481 days (range 1-1794, median 309). Infections occurred in 80 cases (4.7%), with 0.098 per 1000 catheter-days. Among the 80 cases in which chemoports were removed because of suspected infection, bacteria were identified in 48 (60%). Significantly more cases of left internal jugular vein punctures were noted in the infected group (15 [18.8%] vs. 147 [9.1%]; p = 0.004). Pulmonary embolism was significantly different between the infection groups (3 [3.8%] vs. 19 (1.2%), p = 0.048). The hazard ratio was 2.259 (95% confidence interval [CI] 1.288-3.962) for the left internal jugular vein, 3.393 (95% CI 1.069-10.765) for pulmonary embolism, and 0.488 (95% CI 0.244-0.977) for chronic obstructive pulmonary disease. Using the right internal jugular vein rather than the left internal jugular vein when performing chemoport insertion might reduce subsequent infections.


Assuntos
Cateterismo Venoso Central , Embolia Pulmonar , Humanos , Estudos Retrospectivos , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/métodos , Veias Jugulares , Veias Braquiocefálicas , Embolia Pulmonar/epidemiologia , Embolia Pulmonar/etiologia
6.
Sci Rep ; 14(1): 9219, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649477

RESUMO

We investigated the agreement between the jugular bulb (JB) and cerebrospinal fluid (CSF) lactate levels. The study was conducted from July 2021 to June 2023 as a prospective observational cohort study at a single center. The right jugular vein was accessed, and the placement of JB catheter tip was confirmed using lateral cervical spine X-ray. A lumbar catheter was inserted between the 3rd and 4th lumbar spine of the patient. Lactate levels were measured immediately, 24 h, 48 h, and 72 h after ROSC. In patients with a good neurological prognosis, kappa between JB and CSF lactate levels measured immediately, at 24 h, 48 h, and 72 h after ROSC were 0.08, 0.36, 0.14, - 0.05 (p = 0.65, 0.06, 0.48, and 0.75, respectively). However, in patients with a poor neurological prognosis, kappa between JB and CSF lactate levels measured immediately, at 24 h, 48 h, and 72 h after ROSC were 0.38, 0.21, 0.22, 0.12 (p = 0.001, 0.04, 0.04, and 0.27, respectively). This study demonstrated that JB lactate levels exhibited significant agreement with arterial lactate levels, compared to CSF lactate levels. Therefore, this should be considered when using JB lactate to monitor cerebral metabolism.


Assuntos
Veias Jugulares , Ácido Láctico , Parada Cardíaca Extra-Hospitalar , Humanos , Ácido Láctico/líquido cefalorraquidiano , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Parada Cardíaca Extra-Hospitalar/líquido cefalorraquidiano , Estudos Prospectivos , Prognóstico , Biomarcadores/líquido cefalorraquidiano
8.
J Cardiothorac Surg ; 19(1): 122, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38481279

RESUMO

BACKGROUND: Ultrasound-guided percutaneous axillary vein cannulation can reduce cannulation failure and mechanical complications, is as safe and effective as internal jugular vein cannulation, and is superior to subclavian vein cannulation using landmark technique. As far, reports of venovenous extracorporeal membrane oxygenation (VV-ECMO) with percutaneous axillary vein cannulation are rare. CASE PRESENTATION: A 64-year-old man presenting with dyspnea and chest tightness after aspirating sewage was admitted to the emergency department. Computed tomography (CT) showed diffuse exudation of both lungs and arterial blood gas analysis showed an oxygenation index of 86. He was diagnosed with aspiration pneumonia-induced acute respiratory distress syndrome (ARDS) and intubated for deteriorated oxygenation. Despite the combination therapy of protective mechanical ventilation and prone position, the patient's oxygenation deteriorated further, accompanied with multiple organ dysfunction syndrome, which indicated the requirement of support with VV-ECMO. However, vascular ultrasound detected multiple thrombus within bilateral internal jugular veins. As an alternative, right axillary vein was chosen as the access site of return cannula. Subsequently, femoral-axillary VV-ECMO was successfully implemented under the ultrasound guidance, and the patient's oxygenation was significantly improved. Unfortunately, the patient died of hyperkalemia-induced ventricular fibrillation after 36 h of VV-ECMO running. Despite the poor prognosis, the blood flow during ECMO run was stable, and we observed no bleeding complication, vascular injury, or venous return disorder. CONCLUSIONS: Axillary vein is a feasible alternative access site of return cannula for VV-ECMO if internal jugular vein access were unavailable.


Assuntos
Oxigenação por Membrana Extracorpórea , Doenças Vasculares , Masculino , Humanos , Pessoa de Meia-Idade , Oxigenação por Membrana Extracorpórea/métodos , Veia Axilar/diagnóstico por imagem , Cateterismo , Cânula , Veias Jugulares
9.
J Cardiovasc Electrophysiol ; 35(5): 1041-1045, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38462703

RESUMO

INTRODUCTION: Transsubclavian venous implantation of the Aveir leadless cardiac pacemaker (LCP) has not been previously reported. METHODS AND RESULTS: Three cases of transsubclavian implantation of the Aveir LCP are reported. Two cases were postbilateral orthotopic lung transplant, without appropriate femoral or jugular access due to recent ECMO cannulation and jugular central venous catheters. In one case, there was strong patient preference for same-day discharge. Stability testing confirmed adequate fixation and electrical testing confirmed stable parameters in all cases. All patients tolerated the procedure well without significant immediate complications. CONCLUSIONS: We demonstrate the feasibility of transsubclavian implantation of the Aveir LCP.


Assuntos
Estimulação Cardíaca Artificial , Veias Jugulares , Marca-Passo Artificial , Humanos , Masculino , Pessoa de Meia-Idade , Veias Jugulares/cirurgia , Feminino , Idoso , Resultado do Tratamento , Desenho de Equipamento , Implantação de Prótese/instrumentação , Implantação de Prótese/efeitos adversos
13.
Circ Heart Fail ; 17(2): e010973, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38299348

RESUMO

BACKGROUND: Clinical evaluation of central venous pressure is difficult, depends on experience, and is often inaccurate in patients with chronic advanced heart failure. We assessed the ultrasound-assessed internal jugular vein (JV) distensibility by ultrasound as a noninvasive tool to identify patients with normal right atrial pressure (RAP ≤7 mm Hg) in this population. METHODS: We measured JV distensibility as the Valsalva-to-rest ratio of the vein diameter in a calibration cohort (N=100) and a validation cohort (N=101) of consecutive patients with chronic heart failure with reduced ejection fraction who underwent pulmonary artery catheterization for advanced heart failure therapies workup. RESULTS: A JV distensibility threshold of 1.6 was identified as the most accurate to discriminate between patients with RAP ≤7 versus >7 mm Hg (area under the receiver operating characteristic curve, 0.74 [95% CI, 0.64-0.84]) and confirmed in the validation cohort (receiver operating characteristic, 0.82 [95% CI, 0.73-0.92]). A JV distensibility ratio >1.6 had predictive positive values of 0.86 and 0.94, respectively, to identify patients with RAP ≤7 mm Hg in the calibration and validation cohorts. Compared with patients from the calibration cohort with a high JV distensibility ratio (>1.6; n=42; median RAP, 4 mm Hg; pulmonary capillary wedge pressure, 11 mm Hg), those with a low JV distensibility ratio (≤1.6; n=58; median RAP, 8 mm Hg; pulmonary capillary wedge pressure, 22 mm Hg; P<0.0001 for both) were more likely to die or undergo a left ventricular assist device implant or heart transplantation (event rate at 2 years: 42.7% versus 18.2%; log-rank P=0.034). CONCLUSIONS: Ultrasound-assessed JV distensibility identifies patients with chronic advanced heart failure with normal RAP and better outcomes. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03874312.


Assuntos
Insuficiência Cardíaca , Humanos , Pressão Atrial , Cateterismo Cardíaco , Cateterismo de Swan-Ganz , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Veias Jugulares/diagnóstico por imagem , Pressão Propulsora Pulmonar , Volume Sistólico
14.
Am J Case Rep ; 25: e943270, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38379277

RESUMO

BACKGROUND Hyperparathyroidism is a common issue in patients on long-term hemodialysis, necessitating parathyroidectomy with deep venipuncture. These patients frequently exhibit a heightened incidence of vascular calcification, complicating deep venipuncture and increasing the risk of associated complications. Therefore, a crucial aspect of preoperative assessment in this population involves identifying vascular calcification, with a preference for ultrasound-guided intraplane puncture. Special care is required to prevent blood vessel injuries and postoperative complications such as deep vein thrombosis. CASE REPORT We present the case of a 66-year-old woman with secondary hyperparathyroidism who encountered challenges during an internal jugular vein puncture, leading to subsequent thrombosis. Initial attempts were hindered by calcification of the internal jugular vein's vascular wall, resulting in stratified damage to the vessel's wall. However, the ultrasound-guided in-plane puncture technique successfully allowed the insertion of a central venous catheter without further damage to the vascular wall. On the postoperative fourth day, thrombus formation was observed in the damaged vascular wall from the initial puncture. CONCLUSIONS The ultrasound-guided in-plane puncture technique is advantageous in overcoming the difficulties associated with puncturing through deep vein calcification in patients with secondary hyperparathyroidism. This technique also diminishes the likelihood of complications such as venous thrombosis.


Assuntos
Cateterismo Venoso Central , Hiperparatireoidismo Secundário , Trombose , Calcificação Vascular , Feminino , Humanos , Idoso , Cateterismo Venoso Central/efeitos adversos , Flebotomia , Veias Jugulares/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos , Hiperparatireoidismo Secundário/cirurgia
15.
Tomography ; 10(2): 266-276, 2024 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-38393289

RESUMO

OBJECTIVE: Internal Jugular Vein Stenosis (IJVS) is hypothesized to play a role in the pathogenesis of diverse neurological diseases. We sought to evaluate differences in IJVS assessment between CT and MRI in a retrospective patient cohort. METHODS: We included consecutive patients who had both MRI of the brain and CT of the head and neck with contrast from 1 June 2021 to 30 June 2022 within the same admission. The degree of IJVS was categorized into five grades (0-IV). RESULTS: A total of 35 patients with a total of 70 internal jugular (IJ) veins were included in our analysis. There was fair intermodality agreement in stenosis grades (κ = 0.220, 95% C.I. = [0.029, 0.410]), though categorical stenosis grades were significantly discordant between imaging modalities, with higher grades more frequent in MRI (χ2 = 27.378, p = 0.002). On CT-based imaging, Grade III or IV stenoses were noted in 17/70 (24.2%) IJs, whereas on MRI-based imaging, Grade III or IV stenoses were found in 40/70 (57.1%) IJs. Among veins with Grade I-IV IJVS, MRI stenosis estimates were significantly higher than CT stenosis estimates (77.0%, 95% C.I. [35.9-55.2%] vs. 45.6%, 95% C.I. [35.9-55.2%], p < 0.001). CONCLUSION: MRI with contrast overestimates the degree of IJVS compared to CT with contrast. Consideration of this discrepancy should be considered in diagnosis and treatment planning in patients with potential IJVS-related symptoms.


Assuntos
Veias Jugulares , Doenças Vasculares , Humanos , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/patologia , Veias Jugulares/diagnóstico por imagem , Veias Jugulares/patologia , Estudos Retrospectivos , Imageamento por Ressonância Magnética , Doenças Vasculares/patologia , Tomografia Computadorizada por Raios X
16.
Artigo em Inglês | MEDLINE | ID: mdl-38412070

RESUMO

OBJECTIVE: To compare plasma l-lactate (LAC) values between samples collected from jugular and cephalic venipuncture in healthy horses and systemically ill horses. DESIGN: Prospective, experimental study. SETTING: Large animal university teaching hospital. ANIMALS: Thirty healthy adult university-owned horses and 43 client-owned horses presenting to the large animal hospital for elective surgical procedures or for emergent medical evaluation of systemic illness. INTERVENTIONS: Blood samples were collected from the jugular vein (JV) and cephalic vein (CV) and placed in EDTA blood tubes prior to any medical therapy. LAC values were obtained with a handheld lactate meter at the time of blood collection. MEASUREMENTS AND MAIN RESULTS: LAC was higher in CV samples than JV samples in healthy horses (P < 0.001); however, all values were within the normal reference range. Similarly, LAC was higher in CV samples than JV samples in systemically ill horses (P < 0.001), but the median JV value was within normal reference range (1.9 mmol/L [17.1 mg/dL]), while the median CV value was outside the normal reference range (2.9 mmol/L [26.1 mg/dL]). CONCLUSIONS: The CV is an alternative venipuncture site for assessing plasma LAC if the JV is not accessible or to preserve the JV for subsequent catheterization. However, in ill horses, the CV value may be outside the reference range when the corresponding JV value would have been within the reference range.


Assuntos
Ácido Láctico , Sistemas Automatizados de Assistência Junto ao Leito , Animais , Cavalos , Veias Jugulares , Plasma , Estudos Prospectivos
17.
Am J Emerg Med ; 78: 206-214, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38330835

RESUMO

BACKGROUND: Ultrasound-guided central venous catheterization (CVC) has become the standard of care. However, providers use a variety of approaches, encompassing the internal jugular vein (IJV), supraclavicular subclavian vein (SupraSCV), infraclavicular subclavian vein (InfraSCV), proximal axillary vein (ProxiAV), distal axillary vein (DistalAV), and femoral vein. OBJECTIVE: This review aimed to compare the first-pass success rate and arterial puncture rate for different approaches to ultrasound-guided CVC above the diaphragm. METHODS: In May 2023, Embase, MEDLINE, CENTRAL, ClinicalTrials.gov, and World Health Organization International Clinical Trials Platform were searched for randomized controlled trials (RCTs) comparing the 5 CVC approaches. The Confidence in Network Meta-Analysis tool was used to assess confidence. Thirteen RCTs (4418 participants and 13 comparisons) were included in this review. RESULTS: The SupraSCV approach likely increased the proportion of first-attempt successes compared to the other 4 approaches. The SupraSCV first-attempt success demonstrated risk ratios (RRs) > 1.21 with a lower 95% confidence interval (CI) exceeding 1. Compared to the IJV, the SupraSCV approach likely increased the first-attempt success proportion (RR 1.22; 95% confidence interval [CI] 1.06-1.40, moderate confidence), whereas the DistalAV approach reduced it (RR 0.72; 95% CI 0.59-0.87, high confidence). Artery puncture had little to no difference across all approaches (low to high confidence). CONCLUSION: Considering first-attempt success and mechanical complications, the SupraSCV may emerge as the preferred approach, while DistalAV might be the least preferable approach. Nevertheless, head-to-head studies comparing the approaches with the greatest first attempt success should be undertaken.


Assuntos
Cateterismo Venoso Central , Humanos , Metanálise em Rede , Ultrassonografia de Intervenção , Veia Subclávia/diagnóstico por imagem , Veias Braquiocefálicas , Veias Jugulares/diagnóstico por imagem
18.
Acta Anaesthesiol Scand ; 68(4): 520-529, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38351546

RESUMO

BACKGROUND: There is a paucity of data on the incidence of central venous catheter tip misplacements after the implementation of ultrasound guidance during insertion. The aims of the present study were to determine the incidence of tip misplacements and to identify independent variables associated with tip misplacement. METHODS: All jugular and subclavian central venous catheter insertions in patients ≥16 years with a post-procedural chest radiography at four hospitals were included. Each case was reviewed for relevant catheter data and radiologic evaluations of chest radiographies. Tip misplacements were classified as 'any tip misplacement', 'minor tip misplacement' or 'major tip misplacement'. Multivariable logistic regression analyses were used to investigate associations between predefined independent variables and tip misplacements. RESULTS: A total of 8556 central venous catheter insertions in 5587 patients were included. Real-time ultrasound guidance was used in 91% of all insertions. Any tip misplacement occurred (95% confidence interval) in 3.7 (3.3-4.1)% of the catheterisations, and 2.1 (1.8-2.4)% were classified as major tip misplacements. The multivariable logistic regression analyses showed that female patient gender, subclavian vein insertions, number of skin punctures and limited operator experience were associated with a higher risk of major tip misplacement, whereas increasing age and height were associated with a lower risk. CONCLUSIONS: In this large prospective multicentre cohort study, performed in the ultrasound-guided era, we demonstrated the incidence of tip misplacements to be 3.7 (3.3-4.1)%. Right internal jugular vein catheterisation had the lowest incidence of both minor and major tip misplacement.


Assuntos
Cateterismo Venoso Central , Cateteres Venosos Centrais , Humanos , Feminino , Cateterismo Venoso Central/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Estudos Prospectivos , Estudos de Coortes , Ultrassonografia , Veias Jugulares/diagnóstico por imagem , Ultrassonografia de Intervenção
19.
BMC Anesthesiol ; 24(1): 68, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38383304

RESUMO

BACKGROUND: A previous study on mechanical complications after central venous catheterisation demonstrated differences in complication rates between male and female operators. The objective of this subgroup analysis was to further investigate these differences. The hypothesis was that differences in distribution of predefined variables between operator genders could be identified. METHODS: This was a subgroup analysis of a prospective, multicentre, observational cohort study conducted between March 2019 and December 2020 including 8 586 patients ≥ 16 years receiving central venous catheters at four emergency care hospitals. The main outcome measure was major mechanical complications defined as major bleeding, severe cardiac arrhythmia, pneumothorax, arterial catheterisation, and persistent nerve injury. Independent t-test and χ2 test were used to investigate differences in distribution of major mechanical complications and predefined variables between male and female operators. Multivariable logistic regression analysis was used to determine association between operator gender and major mechanical complications. RESULTS: Female operators had a lower rate of major mechanical complications than male operators (0.4% vs 0.8%, P = .02), were less experienced (P < .001), had more patients with invasive positive pressure ventilation (P < .001), more often chose the internal jugular vein (P < .001) and more frequently used ultrasound guidance (P < .001). Male operators more often chose the subclavian vein (P < .001) and inserted more catheters with bore size ≥ 9 Fr (P < .001). Multivariable logistic regression analysis showed that male operator gender was associated with major mechanical complication (OR 2.67 [95% CI: 1.26-5.64]) after correction for other relevant independent variables. CONCLUSIONS: The hypothesis was confirmed as differences in distribution of predefined variables between operator genders were found. Despite being less experienced, female operators had a lower rate of major mechanical complications. Furthermore, male operator gender was independently associated with a higher risk of major mechanical complications. Future studies are needed to further investigate differences in risk behaviour between male and female operators. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT03782324. Date of registration: 20/12/2018.


Assuntos
Cateterismo Venoso Central , Cateteres Venosos Centrais , Feminino , Humanos , Masculino , Cateterismo Venoso Central/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Veias Jugulares , Estudos Prospectivos , Fatores Sexuais , Ultrassonografia , Adolescente , Estudos Multicêntricos como Assunto , Estudos Observacionais como Assunto , Adulto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...